PF Power Fittings Technical Reference

JGP HV Cable Fixing Clamp

Models: JGP-1 – JGP-8 · Cable OD: 45–145 mm · Bolting: 2-M12 to 2-M16

Read W Carefully — It Is Not the JGH’s W

Four columns: L, W, L1, M. And the trap is W.

On the JGH page W is the width of the clamp body, 60 to 85 mm. On this page W is the overall width including the mounting bracket, and it runs 180 to 388 mm.

Check it against L:

Model L W W − L
JGP-3 210 246 36
JGP-5 250 290 40
JGP-7 315 358 43
JGP-8 345 388 43

W is consistently about 40 mm more than L on every row. So the two numbers describe one part from two directions, and the 40 mm is the tail of the base plate.

Carry a W from this page onto a JGH drawing and you will be 150 mm out. Use L for the clamp and W for the footprint, and check both against the structure.

The Ranges Leave No Gaps

4555, 5568, 6880, 8090, 90100, 100114, 114130, 130145.

Eight clamps, contiguous, no gaps and no overlaps. Every cable from 45 to 145 mm is covered by exactly one size, which is not true of every clamp page in this catalogue — the JGHD has both a gap and an overlap.

The steps are 10 to 15 mm and they widen as the cable grows, so the small sizes are the finer ones — the opposite of the JGH, where the middle of the range is finest.

L1 Goes Down at the Top

L1 — the mounting offset — climbs 60, 65, 70, 80, 80, 90, 100 and then drops to 90 on JGP-8.

The largest clamp in the family, 345 mm long and taking a 145 mm cable, has a smaller mounting offset than the JGP-7. L is 30 mm longer and L1 is 10 mm shorter, so the extra length has gone into the jaw, not the base.

That is the one row to look at twice if you are replacing a JGP-7 with a JGP-8 on an existing bracket: the clamp grows but the bolt hole moves back.

Bolting Steps Twice

2-M12 on JGP-1 and JGP-2, 2-M14 on JGP-3 to JGP-5, 2-M16 on JGP-6 to JGP-8.

Two bolts per clamp throughout, and the bolt size changes at a different point from the cable size — M14 starts at 68 mm cable, M16 at 100 mm. If you are matching an existing stud pattern, the bolt is the constraint long before the jaw is: a JGP-5 and a JGP-6 take the same cable within 100 mm but not the same bolt.

Technical Parameters

JGP HV Cable Fixing Clamp JGP HV Cable Fixing Clamp

ModelApplicable Cable OD (mm)Main Dimensions (mm)
LWL1M
JGP-145~55150180602-M12
JGP-255~68186214652-M12
JGP-368~80210246702-M14
JGP-480~90245288802-M14
JGP-590~100250290802-M14
JGP-6100~114280320902-M16
JGP-7114~1303153581002-M16
JGP-8130~145345388902-M16

The narrow-body clamp: JGH cable fixing clamp. The heavy standoff version: JGHD cable fixing clamp. Other clamps in the family: JGW, JGW2, JGW3, JGWD.

Note: W on this page is the overall width including the bracket, about 40 mm more than L — it is not the body width it is on the JGH. The cable ranges are contiguous, 45 to 145 mm. L1 drops from 100 to 90 on the largest size.

Sizing data behind this page

A cable fixing clamp is chosen by the cable's overall diameter and sheath, not by its conductor area. The overall diameters for the cables in this catalogue are in: