10kV Overhead Insulated Line Strain Assembly Diagrams

Assemblies: 4 · Line items: 24 · Voltage: 10 kV · Clamps: NXJG, NXL, NXG · String: single (3 diagrams) and double (1)

What These Four Sheets Are

Each diagram is a dead-end on an insulated overhead line: a short span of hardware that takes the conductor tension and hands it to the pole. Read as a set they run from the simplest (four parts) to a double-string assembly (eleven parts).

The parts repeat across the four, and that is the useful thing on the page — twelve of the twenty-four line items use a code that appears in more than one diagram, so a project that needs several pole types can pool the hardware:

Code Part Appears in
NXJG Wedge strain clamp 1, 2
QP-0750 Ball-eye 2, 3, 4
Z-0780 Z-type clevis 3, 4
WS-0770 Socket clevis 3, 4

That leaves the pole-end fittings — the shackles, the yoke, the extension link and the two parallel clevises, PD-0770 and PD-12100 — as the genuinely different parts.

The Insulator Comes From The Project Bill

Every diagram has an insulator row: in diagram 1 named (double iron-head porcelain rod, quantity 1) and in diagrams 2, 3 and 4 carried as Insulator for the project to fill in. It is the one component that sets the creepage distance, the dry-arc distance and the mechanical rating of the string, and it is the one component specified against the line insulation level rather than against a fitting code.

This page assembles the fittings; it does not specify the insulator. Send us the insulator’s pin and cap sizes with the enquiry and we will confirm that QP-0750, WS-0770 and the clevises couple to it — that is the interface between our hardware and your insulator.

The Codes Carry A Load Class, And The Double String Steps It Up

Look at what happens in diagram 4, the two-string assembly:

  • Top of the string, in the 12 class: U-1290 shackle (×2), PH-12120 extension link, L-12-70/400 yoke plate (×2), Z-12100 clevis, PD-12100 parallel clevis.
  • Below the yoke, still in the 07 class: Z-0780 (×2), QP-0750 (×2), WS-0770 (×2), NXG clamp.

So the fittings that carry both strings are rated one step higher, and the per-string hardware stays where it was in the single-string diagrams. Two strings of the same hardware pulled in parallel need a heavier shackle and yoke — and that is exactly what the codes show.

Read the first pair of digits as a series, not a size. 07 parts appear in all four diagrams; 12 parts appear only in the double-string one. It is a family marker that tracks the duty, and it is the reason U-0770 and U-1290 are not interchangeable even though both are shackles.

The Last Two Digits Do Not Stay Constant Within One Assembly

If the trailing digits were a coupling size, every part in one diagram would carry the same one. They do not:

  • Diagram 1: ZBD-07-80, PD-07-70 — an 80 at the top and a 70 below it.
  • Diagram 3: Z-07-80, QP-07-50, WS-07-70 — three different endings in one four-part string.

So the trailing two digits carry the fitting’s own pin or hole size, not a coupling class shared across a string. That is why a set is checked against the insulator’s pin and cap drawing and not by reading the codes across the list — the drawing is what the coupling is built to.

What The Assembly Drawing Adds

The four tables list fittings, so the string-level figures come with the drawing rather than with the parts:

  • Assembly rating — each clamp carries its own rated failing load on its own page; the string rating is set by the weakest item and is confirmed on the assembly drawing.
  • String dimensions — overall length, yoke-to-clamp distance and creepage are dimensioned on the drawing for the insulator you specify.
  • Consumables — bolts, split pins and armour rods are quoted with the assembly, priced per string.
  • Earthing — a 10 kV insulated dead-end normally needs a bonding item on the pole side; tell us the pole type and we add it to the list.

Technical Parameters

10kV Overhead Insulated Line Strain Assembly Diagrams

No.NameModel/SpecificationQty
1ZBD ClevisZBD-07-801
2Double Iron-Head Porcelain Rod1
3PD Parallel ClevisPD-07701
4Wedge-Type Strain ClampNXJG1

10kV Overhead Insulated Line Strain Assembly Diagrams

No.NameModel/SpecificationQty
1U-Type ShackleU-07702
2Ball-EyeQP-07501
3Insulator
4Socket ClevisW-07701
5Wedge-Type Strain ClampNXJG1

10kV Overhead Insulated Line Strain Assembly Diagrams

No.NameModel/SpecificationQty
1Z-Type ClevisZ-07801
2Ball-EyeQP-07501
3Insulator
4Socket ClevisWS-07701
5Wedge-Type Strain ClampNXL1

10kV Overhead Insulated Line Strain Assembly Diagrams

No.NameModel/SpecificationQty
1U-Type ShackleU-12902
2PH Extension LinkPH-121201
3Yoke PlateL-12-70/4002
4Z-Type ClevisZ-07802
5Ball-EyeQP-07502
6Insulator
7Socket ClevisWS-07702
8Z-Type ClevisZ-121001
9PD Parallel ClevisPD-121001
10Wedge-Type Strain ClampNXG1

Note: Four dead-end assemblies, 24 line items. The 07 series runs through all four; the 12 series appears only in the two-string diagram, where the shackle, extension link and yoke are upsized to carry both strings. Trailing digits are the pin or hole size of the individual fitting, so a set is matched to the insulator’s pin and cap drawing. The insulator and the string figures — rating, length, creepage, consumables — come with the assembly drawing for the project you are building.