Insulated Conductor Fitting Installation Diagrams
Photographs: 8 · Numbered positions: 1–6 · Named parts: NXJG, JBLY · Voltage: 10 kV class insulated overhead line
What This Page Is, And What It Is Not
This is a photographic record of where the hardware goes, not a product sheet. Eight pictures of real lines — concrete poles, covered conductor, spool insulators, a pole-mounted transformer — each with one fitting ringed in red and a number beside it.
The numbers run 1 to 6, and they repeat across the photographs: 1 appears in images 1 and 5, 2 in images 1, 5 and 7, 3 in images 1, 6 and 8, 4 in images 2 and 8, 5 in image 3, 6 in image 4.
The sheet prints no key. Nothing on this page says what position 1, 2 or 3 is. The only two parts the text names are the NXJG insulated strain clamp and the JBLY shaped parallel groove clamp with its insulating cover.
So read the photographs as evidence of the jobs the fittings do, not as an assembly drawing. For dimensions and ratings, go to the two product sheets.
The Six Positions, As Photographed
What can be said without a key is where each circle sits:
- 1 — the dead-end. A wedge clamp at the end of a crossarm, holding the covered conductor against a spool insulator. Images 1 and 5 both show it at a termination, on two different pole designs.
- 2 — mid-span, phase to phase. A clamp on a live conductor away from any insulator — a tap or a jumper take-off. Image 7 shows the same position on a clean crossarm with three phases visible.
- 3 — a connector on the tap. Images 1 and 6 show it on the conductor leaving the pole hardware; image 8 shows it on a covered conductor running past a pole.
- 4 — a mid-span fitting above a transformer. Image 2 rings it on a conductor below the crossarm; image 8 rings the same number in an inset detail.
- 5 — under a pin insulator. Image 3, at the end of a horizontal insulator, clamp and all.
- 6 — a fitting being worked live. Image 4, a linesman in gloves on the pole, the clamp ringed at the top of the frame.
Numbers 1 and 3 are the two that recur most, which fits the text: a dead-end clamp and a tap connector are the two things this family is made of.
The Photographs Show What The Sheets Do Not
Three things are visible here and printed nowhere in the catalogue:
- The insulating covers are part of the picture. Nearly every ringed fitting is covered — the clamp bodies are sleeved, the taps are booted. Buying the clamp alone leaves an exposed joint. The cover family is on its own page.
- Two conductor types in the same photograph. Image 3 shows bare conductor on one crossarm and covered conductor on the one below it, both with the same class of fitting. The clamp has to suit the conductor’s outer diameter, not its square millimetres.
- The same fitting on wooden-class and concrete poles. The pole type changes the bracket, not the clamp; every position shown is a conductor-to-conductor or conductor-to-insulator joint.
What You Cannot Get From This Page
- No model, size or quantity for anything except NXJG and JBLY, and no size for those either.
- No key to the six numbers — the numbering belongs to the original catalogue and its legend is not reprinted here.
- No installation torque, no bolt size, no tightening sequence.
- No conductor range — the photographs show the fittings on several conductor sizes and none is stated.
Use this page to brief an installer or to show a customer what “fully insulated” looks like. Use the NXJG and JBLY sheets to quote.
The Eight Sites

Positions 1, 2 and 3 on one pole: the dead-end, a mid-span tap, and the connector on the tap. The transformer below is fed from the same crossarm.

Position 4. Covered conductor on a double crossarm, every phase held in a spool insulator with the fitting ringed on the lower run.

Position 5, and the clearest view of the two conductor types on one pole — bare above, covered below.

Position 6 — a linesman working the fitting in insulating gloves, which is the point of the covers: the joint is touchable.

Positions 1 and 2 again, on a pole-mounted transformer station with a metering box.

Position 3 at the transformer terminals themselves, with phase-coloured covers on the bushings.

Position 2 on a clean three-phase crossarm: the clamp sits mid-span, well away from the insulators.

Position 3 with position 4 in the inset.
Related Pages
The dead-end clamp shown at most of these positions: NXJG wedge-type insulated strain clamp. The tap clamp with its cover: JBLY parallel groove clamp. Covers for the joints that stay exposed: PZ insulating cover. Terminal covers at the transformer: power transformer terminal safety cover. Where these fittings sit in a whole station: pole-mounted transformer area.
Note: Eight site photographs and six numbered positions, with no legend anywhere on the sheet — numbers 1 and 3 recur most, and the only parts named in the text are NXJG and JBLY. What the pictures do show is that the covers are part of the installation, that bare and covered conductor use the same class of fitting, and that the joint is meant to be touchable. No sizes, torques, quantities or conductor ranges are printed.