NXG Wedge Insulated Strain Clamp for JKLGYJ Cable

The NXG is the clevis-pattern wedge clamp for JKLGYJ steel-cored aluminum overhead insulated cable at 10 kV and below. Nothing is stripped at the pole: the wedge core bites through the insulation, the clamp seats with a wedge and a hammer, and an insulation cover closes over the body afterwards. Ten order codes cover 35/6 to 300/25 conductor, split into a 1 kV set and a 10 kV set. Chinese patent 201020566448.7.
Technical Parameters
1 kV — JKLGYJ-1
| Model | Sample Model Before 2013 | Applicable Wire (mm2) | 1kV (JKLGYJ) Steel Core Aluminum Stranded Wire Overhead Insulated Cable | Nominal Failure Load (kN) | |
|---|---|---|---|---|---|
| Wire Outer Diameter (mm) | Selected Wedge Core | ||||
| NXG-1(1kV) | NXJ-1C-G | 35/6 | 10.6 | NXJ-1C-G-A | 19.3 |
| 50/8 | 11.9 | ||||
| NXG-2(1kV) | NXJ-2C-G | 70/10 | 13.7 | NXJ-2C-G-A | 22.2 |
| NXJ-3C-G | 95/15 | 16.1 | NXJ-3C-G-B | 39.0 | |
| 95/20 | 16.3 | ||||
| NXG-3(1kV) | NXJ-4C-G | 120/7 | 16.8 | NXJ-4C-G-C | 50.3 |
| 120/20 | 17.6 | ||||
| 120/25 | 17.9 | ||||
| 150/8 | 18.7 | ||||
| 150/20 | 19.4 | ||||
| NXG-4(1kV) | NXJ-5C-G | 185/10 | 20.7 | NXJ-5C-G-D | 87.6 |
| 185/25 | 21.7 | ||||
| 185/30 | 21.7 | ||||
| 185/45 | 22.4 | ||||
| 240/30 | 24.4 | ||||
| 240/40 | 24.5 | ||||
| NXG-5(1kV) | NXJ-5C-G | 300/15 | 26.2 | NXJ-5C-G-C | 87.6 |
| 300/20 | 26.4 | ||||
| 300/25 | 26.7 | ||||
Note: Cast from high-strength aluminum alloy with no magnetic hysteresis loss. The cable does not need its insulation stripped and installation needs no special tools — the wedge structure does the work.
10 kV — JKLGYJ-10
| Universal Design Model | Model | Applicable Wire (mm2) | 10kV (JKLGYJ) Steel Core Aluminum Stranded Wire Overhead Insulated Cable | Nominal Failure Load (kN) | |
|---|---|---|---|---|---|
| Wire Outer Diameter (mm) | Selected Wedge Core | ||||
| NXG-1(10kV) | NXJ-3C-G | 35/6 | 16.0 | NXJ-3C-G-B | 39.0 |
| 50/8 | 17.0 | ||||
| NXG-2(10kV) | NXJ-3C-G | 70/10 | 19.2 | NXJ-3C-G-A | 39.0 |
| 95/15 | 21.6 | ||||
| 95/20 | 21.9 | ||||
| NXG-3(10kV) | NXJ-4C-G | 120/7 | 22.5 | NXJ-4C-G-B | 50.3 |
| 120/20 | 23.1 | ||||
| 120/25 | 23.7 | ||||
| 150/8 | 24.0 | NXJ-4C-G-A | |||
| 150/20 | 24.7 | ||||
| NXG-4(10kV) | NXJ-5C-G | 185/10 | 26.0 | NXJ-5C-G-B | 87.6 |
| 185/25 | 26.9 | ||||
| 185/30 | 26.9 | ||||
| 185/45 | 27.6 | ||||
| 240/30 | 29.6 | NXJ-5C-G-A | |||
| 240/40 | 29.7 | ||||
| NXG-5(10kV) | NXJ-5C-G | 300/15 | 29.8 | NXJ-5C-G-A | 87.6 |
| 300/20 | 29.8 | ||||
| 300/25 | 30.3 | ||||
Note: Dimensions may vary slightly with manufacturing tolerance. Contact our engineering team for custom sizes.
Why the 10 kV Table Starts at a Bigger Body
Compare the same conductor across the two tables and the gap is plain: 35/6 measures 10.6 mm at 1 kV and 16.0 mm at 10 kV, 95/15 goes 16.1 to 21.6, 240/40 goes 24.5 to 29.7. That is 3.4 to 5.8 mm of extra insulation, and it costs you two body sizes.
A 10 kV 35/6 is as fat as a 1 kV 120/7. The 1 kV set starts at the smallest casting, NXJ-1C-G, while the 10 kV set starts at NXJ-3C-G and never touches the two smallest. Stocking for both voltage classes, you need 3C, 4C and 5C either way; the small two are 1 kV only.
The Wedge Core Is the Real Part Number
The NXG codes are ordering groups, not castings. The column headed Selected Wedge Core is the part that actually gets stocked — an NXJ body with a lettered core in it — and a single NXG code can span two bodies.
At 1 kV, NXG-2 carries 70/10 on an NXJ-2C-G-A core but 95/15 and 95/20 on an NXJ-3C-G-B. One order code, two different castings. Across the ten codes there are five bodies: NXJ-1C-G through NXJ-5C-G, of which only the three largest appear at 10 kV.
On the NXJ-5C-G body alone the sheet lists four cores, A to D, reaching from 20.7 mm up to 30.3 mm. The letters run backwards from what most people guess: A is the largest core, D the smallest.
- NXJ-4C-G: C covers 16.8–19.4 mm, B covers 22.5–23.7 mm, A covers 24.0–24.7 mm
- NXJ-5C-G: D covers 20.7–24.5 mm, C covers 26.2–26.7 mm, B covers 26.0–27.6 mm, A covers 29.6–30.3 mm
So NXG-4 and NXG-5 at 1 kV are the same casting with a different core in it, and NXG-1 and NXG-2 at 10 kV are both on NXJ-3C-G. Order the core by diameter rather than by the NXG number.
One warning the table hides: on the NXJ-5C-G body the B and C cores overlap — 26.0–27.6 mm against 26.2–26.7 mm. Diameter alone will not choose between them, because the two are cut for different insulation: C serves the 1 kV 300 mm² entries, B the 10 kV 185 mm² entries. Give us conductor size and voltage class, not just diameter.
Fitting It
The clamp hangs on a clevis, so the insulator string end fitting decides the pin. Conductor preparation is the part that catches crews out the first time: nothing is stripped, and that is the design intent — but the cable end must be square-cut, dry, and free of semi-conducting compound smeared along the sheath, or the core will not seat. Drive the wedge until it is flush with the body, then fit the insulation cover before the clamp goes up.
Rated failure loads run 19.3 kN to 87.6 kN at 1 kV and 39.0 to 87.6 kN at 10 kV. The 1 kV NXG-1 at 19.3 kN is a light clamp — it suits 35/6 and 50/8 service drops, not a full-tension dead-end on a main line.
Material and Finish
- Body and wedge: high-strength cast aluminum alloy, no magnetic hysteresis loss
- Hardware: hot-dip galvanized steel
- Galvanizing: ISO 1461 / ASTM A153, minimum coating 65 μm
- Tolerance: ±0.5 mm on the wedge seat and clevis
- Inspection: dimensional check, coating thickness to ISO 2178, grip test on samples; mill test certificates on request
Related Wedge Clamps
For plain aluminum JKLYJ cable rather than steel-cored JKLGYJ, the NXJG clevis wedge clamp is the same principle on a different body set, and the NXJL tie-rod version replaces the clevis with a tension rod. Where the conductor has to be stripped and a bare wedge used, see the NXL wedge clamp. For a bolted joint on the same cable, the NLL bolted aluminum clamp needs no wedge at all.