Models: PS-7 – PS-30 · Nominal Failure Load: 70–300 kN · Reference Weight: 0.60–5.30 kg · Mouth C: 20–38 mm · Pin hole Φ: 20–39 mm

One Mouth, Three Ratings

The PS carries both a bolt and a pin — M closes the mouth, Φ is the hole through the legs — and it holds the mouth still at the bottom of the range:

Model C b M Φ H Load Weight
PS-7 20 16 16 20 90 70 kN 0.60 kg
PS-10 20 20 18 20 90 100 kN 0.80 kg
PS-12 20 20 22 24 95 120 kN 1.50 kg
PS-16 26 24 24 26 155 160 kN 2.70 kg
PS-30 38 34 36 39 140 300 kN 5.30 kg

70, 100 and 120 kN all take a 20 mm tongue and stand 90 to 95 mm high. If your bracket is built for a 20 mm mouth, you can move up two ratings without changing anything around the fitting. That is worth having, and it is unusual on the site.

The 120 kN Costs Double

PS-10 and PS-12 share the mouth (20 mm) and the plate thickness (20 mm). Between them the pin hole goes 20 → 24 mm, the bolt 18 → 22 mm and the height 90 → 95 mm — and the weight goes 0.80 → 1.50 kg.

On a part where the width and thickness have not changed, that is 0.70 kg of metal for one step of 20 kN — the 120 kN plate is wider where the table does not show it, and the packing list is where that reads. Price the 120 kN size from the packing-list weight.

H Drops at the Top

90, 90, 95, 155, 140. The 300 kN part is 15 mm shorter than the 160 kN part. So the tallest PS clevis is not the strongest one — it is the 160 kN.

If you are choosing for reach rather than load, that is the line to take: PS-16 clears more than PS-30.

Two Sizes in the Heading, Five in the Table

The heading quotes PS-0790 to PS-10100, two sizes, because those are the only ones with design numbers. The table carries five PS models up to 300 kN — PS-12, PS-16 and PS-30 exist under the model numbers only.

And the two design rows do not match their model twins exactly:

C b M Φ H
PS-7 20 16 16 20 90
PS-0790 20 16 16 18 90
PS-10 20 20 18 20 90
PS-10100 20 18 18 20 100

Two millimetres on the pin and on the plate, 10 mm on the height. Not interchangeable — read the full number.

Technical Parameters

General Design No.ModelMain Dimensions (mm)Nominal Failure Load (kN)Reference Weight (kg)
CbMΦH
PS-72016162090700.60
PS-1020201820901000.80
PS-1220202224951201.50
PS-16262424261551602.70
PS-30383436391403005.30
PS-07902016161890700.60
PS-10100201818201001000.80

Bolt-closed plate version: P clevis. Flat two-hole link: PD clevis. Forged U: U clevis. Two-bolt link: UB clevis. V-shaped: V clevis.

Note: C stays at 20 mm for 70, 100 and 120 kN, so two ratings can be added without changing the bracket. H is not monotone — PS-30 at 140 mm is shorter than PS-16 at 155 mm. The 120 kN part weighs 0.70 kg more than the 100 kN one without any change in mouth or plate thickness.

Sizing data behind this page

The sizes above are nominal. What a conductor of that nominal size actually measures — outer diameter, calculated breaking load, weight per kilometre — is what a clamp groove or a sleeve bore is matched against, and it is in these tables: