PF Power Fittings Technical Reference

FDY Vibration Damper

Models: FDY-1/2 – FDY-4/6 · Rows: 7 · Conductor: 12–35 mm diameter · Reference Weight: 1.5–5.8 kg

Read the Slash

This is the clearest numbering rule in the damper range, and it is worth learning because it applies to the FR sheet as well:

  • The number before the slash is the body — the messenger and the weights. It fixes L, D and H.
  • The number after the slash is the clamp — the jaw that grips the conductor. It fixes the conductor range and adds a little weight.

Check it against the table. FDY-3/4 and FDY-3/5 share L 450, D 56, H 97, a 60, L1 150 and differ only in conductor range, 18–22.5 against 22.5–30, and by 0.4 kg. FDY-4/5 and FDY-4/6 share L 500, D 62, H 97, a 60, L1 175 the same way.

So one body covers two conductor sizes — you are choosing a clamp, not a damper. That is why the weights within a body pair are so close.

Two Dampers for the Same Conductor

FDY-1/2 and FDY-2 both cover 12.0–16.0 mm. They are not duplicates:

Model Conductor L L1 Weight
FDY-1/2 12.0–16.0 300 95 1.5 kg
FDY-2 12.0–16.0 370 130 2.4 kg

Body 1 is short and light; body 2 is 70 mm longer and 0.9 kg heavier. Both are correct for the same conductor — the choice is the span and the expected vibration level, not the cable.

The rule of thumb on this page: the short body for a short span or a low-vibration site, the long body where the conductor is exposed to steady cross-wind. If a client specifies “FDY for 12–16 mm” they have not finished the specification; ask for the span.

H Steps With the Body

H runs 81 mm on bodies 1 and 2, 97 mm on bodies 3 and 4. That 16 mm step is the change from a two-piece to a three-piece messenger, and it is the only dimension that tells bodies 1–2 from 3–4 without reading the weight.

D follows the same split: 40 and 46 mm on the small bodies, 56 and 62 on the large. L, D and H all move together with the body number — which is exactly what makes the slash rule useful.

Technical Parameters

FDY Vibration Damper

ModelApplicable Conductor Dia.(mm)Main Dimensions(mm)Reference Weight(kg)
LDHaL1
FDY-1/212.0~16.0300408150951.5
FDY-212.0~16.03704681501302.4
FDY-2/316.0~18.03704681501502.5
FDY-3/418.0~22.54505697601504.1
FDY-3/522.5~30.04505697601504.5
FDY-4/522.5~30.05006297601755.6
FDY-4/630.0~35.05006297601755.8

The same body-and-clamp scheme with a shorter head: FR vibration damper. Small conductors: FDZ, FDB. Large ACSR: FD, FD-L. Full selection table: FDN.

Note: the number before the slash is the body and after it the clamp — FDY-3/4 and FDY-3/5 are the same damper with two jaws. FDY-1/2 and FDY-2 both serve 12–16 mm at 1.5 and 2.4 kg; the choice depends on span, not conductor.

Sizing data behind this page

The sizes above are nominal. What a conductor of that nominal size actually measures — outer diameter, calculated breaking load, weight per kilometre — is what a clamp groove or a sleeve bore is matched against, and it is in these tables: