JPL FJP Grading Shielding Ring
Models: JPL-1200×860 – FJP-1300×1200 · Rows: 15 · Reference Weight: 4.3–18.2 kg
Fifteen Rows, Three Different Things
This table is not one family. Read the model column and it splits:
- JPL-1200×860 and JPL-1550×860 — the two large rings, with a tall bracket (H 850) and a second mounting position at H1 425.
- FJP-500B1 to FJP-500B9 — nine rings in the 500 class, each with a different mounting arrangement.
- JL1-760×660, JL1-1026×660, JL1-1026×660c and FJP-1300×1200 — four individual rings at the end of the list.
They are on one sheet because they share the same columns, not because they are a series. The columns change meaning between blocks — which is the subject of the next section.
The B Numbers Are Brackets, Not Sizes
All nine read FJP-500, and the number after B is not a size step. The evidence is in the L and B columns:
1000, 820, 1000, 900, 660, 1060, 620, 1060, 776.
There is no order to it — 620 between 1060 and 1060, and 776 with no relation to either neighbour. What does change, row by row, is which mounting dimensions are filled in:
| H | H1 | a | a1 | C | |
|---|---|---|---|---|---|
| B1 | 150 | — | 40 | 50 | 50 |
| B2 | 150 | — | 40 | 50 | 50 |
| B3 | 125 | — | 80 | — | 23 |
| B4 | 125 | — | 80 | — | 23 |
| B5 | — | — | 50 | — | 22 |
| B6 | 310 | — | 40 | — | 50 |
| B7 | — | — | 50 | — | 20 |
| B8 | 500 | — | 80 | — | 18 |
| B9 | 260 | — | 80 | — | 24 |
A blank cell means the dimension does not apply to that bracket, not that it is zero. B5 and B7 have no H at all — they are flat rings that mount directly against the hardware. B1 and B2 are the only rows with both a and a1 filled, and on B3 and B4 the depth that a1 covered is now carried by C.
So you cannot read across the block. Read one row at a time, and take the columns in the header order printed for that row.
One Clean Number: B3 Against B4
Between the two rows that share a bracket, the arithmetic works exactly:
| Model | L | B | H | C | Weight |
|---|---|---|---|---|---|
| FJP-500B3 | 1000 | 660 | 125 | 23 | 5.9 kg |
| FJP-500B4 | 900 | 660 | 125 | 23 | 5.3 kg |
Everything is identical but L, and 100 mm of extra L is 200 mm of extra loop — about 0.65 kg of steel at 23 mm tube. The sheet says 0.6 kg. That is the only pair on the page where the weight column can be checked and it passes.
Keep that rate in mind for the next section.
The Two JPL Rings Scale With The Loop
JPL-1200×860 is 17.6 kg. JPL-1550×860 is 18.2 kg.
Same B 860, same H 850, same 20 mm bar — only L moves, by 350 mm. On an ellipse, 350 mm of L adds about 600 mm of loop, and 600 mm of 20 mm bar is 0.6 kg. The 0.6 kg step is the extra bar, and it is the whole of the difference.
Now compare across to the 500 class: a 1000 mm ring there weighs 5.9 kg because its B is 660 and its bracket stands 125 mm, against 860 and 850 on the JPL pair. Loop plus bracket sets the mass — which is why a wide ring on a half-metre standoff is three times the weight of a flat one of the same length.
One Ring, Two Orientations
Two rows at the end of the table:
| Model | L | B | H | C | Weight |
|---|---|---|---|---|---|
| JL1-1026×660 | 660 | 1026 | 260 | 24 | 6.5 kg |
| JL1-1026×660c | 1026 | 660 | 260 | 24 | 6.5 kg |
Same ring, entered once with the axes the right way round and once with them swapped. Both weigh 6.5 kg and both take the same bracket, so it is one part under two rows.
Quote JL1-1026×660c — it carries the orientation the model number promises, and that matters to any check on L ≤ B or on a clearance envelope.
Technical Parameters

| Model | Diagram | Main Dimensions (mm) | Reference Weight (kg) | ||||||
|---|---|---|---|---|---|---|---|---|---|
| L | B | H | H1 | a | a1 | C | |||
| JPL-1200×860 | 1 | 1200 | 860 | 850 | 425 | 80 | 40 | 20 | 17.6 |
| JPL-1550×860 | 1 | 1550 | 860 | 850 | 425 | 100 | 40 | 20 | 18.2 |
| FJP-500B1 | 2 | 1000 | 660 | 150 | 40 | 50 | 50 | 5.8 | |
| FJP-500B2 | 2 | 820 | 660 | 150 | 40 | 50 | 50 | 5.2 | |
| FJP-500B3 | 3 | 1000 | 660 | 125 | 80 | 23 | 5.9 | ||
| FJP-500B4 | 3 | 900 | 660 | 125 | 80 | 23 | 5.3 | ||
| FJP-500B5 | 2 | 660 | 700 | 50 | 22 | 4.3 | |||
| FJP-500B6 | 4 | 1060 | 660 | 310 | 40 | 50 | 6.6 | ||
| FJP-500B7 | 5 | 620 | 900 | 50 | 20 | 5.7 | |||
| FJP-500B8 | 6 | 1060 | 660 | 500 | 80 | 18 | 6.7 | ||
| FJP-500B9 | 7 | 776 | 676 | 260 | 80 | 24 | 5.7 | ||
| JL1-760×660 | 7 | 760 | 660 | 260 | 80 | 24 | 5.6 | ||
| JL1-1026×660 | 8 | 660 | 1026 | 260 | 80 | 24 | 6.5 | ||
| JL1-1026×660c | 8 | 1026 | 660 | 260 | 80 | 24 | 6.5 | ||
| FJP-1300×1200 | 9 | 1300 | 1200 | 430 | 80 | 18 | 7.3 | ||
Related Pages
The FJ loops without brackets: FJ grading ring, FJ 660, FJV. The FP bracket-kit rings: FP shielding ring. 330 kV assemblies: Shielding ring 330 kV.
Note: the FJP-500B numbers are nine bracket variants of one 500-class ring, not a size range — blanks mean “not applicable”, not zero. FJP-500B3 and B4 give a clean 0.6 kg per 100 mm of L; the JPL pair gives 0.6 kg for 350 mm, which cannot be right. JL1-1026×660 and JL1-1026×660c are one ring entered in two orientations.