PF Power Fittings Technical Reference

ACSR/AW Conductor Table, IEC 61089 Type A1/S1A

37 rows · 21 code numbers · 16 to 1250 mm² · plain aluminium over aluminium-clad steel · Table D.4

ACSR/AW is plain aluminium wires over an aluminium-clad steel core. GB/T 1179 writes it JL/LB1A; IEC 61089 writes it A1/S1A — A1 for hard-drawn aluminium, S1A for the clad steel core, and the slash means the two metals are stranded together rather than alloyed.

Two neighbours are easy to confuse with it, and neither is this conductor:

  • ACSR — the same plain aluminium, but the core is hot-dip galvanised steel, A1 in IEC and LGJ in GB. The zinc is the difference: it is a coating that is consumed, and once it is gone the core rusts.
  • AACSR/AW — the same clad core, but the outer layer is aluminium alloy, not plain aluminium. That is A2/S1A in IEC and JLHA1/LB1A in GB.

So the aluminium-clad core buys corrosion resistance at the coast and in industrial air, where a galvanised core has a service life measured in the zinc mass. It costs conductivity: the clad steel is a poorer conductor than the aluminium it displaces, and the steel ratio below decides how much.

Code No.Steel Ratio %Al Area mm²Steel Area mm²Total Area mm²Wires Al/StWire Dia Al/St mmCore Dia mmConductor Dia mmMass kg/kmRated Strength kNDC Resistance at 20 °C Ω/km
1617162.6718.76/11.84/1.841.845.5364.66.061.7934
2517254.1729.26/12.30/2.302.306.91100.99.131.1478
4017406.6746.76/12.91/2.912.918.74161.514.400.7174
63176310.573.56/13.66/3.663.6611.0254.421.630.4555
1001710016.71176/14.61/4.614.6113.8403.834.330.2869
12561256.9413218/12.97/2.972.9714.9397.929.170.2304
1251612520.414526/72.47/1.925.7715.7503.945.690.2310
16061608.8916918/13.36/3.363.3616.8509.336.180.1800
1601616026.118626/72.80/2.186.5317.7644.957.690.1805
200620011.121118/13.76/3.763.7618.8636.744.220.1440
2001620032.623326/73.13/2.437.3019.8806.270.130.1444
2501025024.627522/73.80/2.116.3421.6880.668.720.1154
2501625040.729126/73.50/2.728.1622.21007.787.670.1155
315731521.833745/72.99/1.995.9723.91039.679.030.0917
3151631551.336626/73.93/3.059.1624.91269.7106.830.0917
400740027.742845/73.36/2.246.7326.91320.198.360.0722
4001340051.945254/73.07/3.079.2127.61510.3123.040.0723
450745031.148145/73.57/2.387.1428.51485.2107.470.0642
4501345058.350854/73.26/3.269.7729.31699.1138.420.0643
500750034.653545/73.76/2.517.5230.11650.2119.410.0578
5001350064.856554/73.43/3.4310.330.91887.9153.800.0578
560756038.759945/73.98/2.657.9631.81848.2133.740.0516
5601356070.963154/193.63/2.1810.932.72103.4172.590.0516
630763043.667445/74.22/2.818.4433.82079.2150.450.0459
6301363079.871054/193.85/2.3111.634.72366.3191.770.0459
710771049.175945/74.48/2.998.9635.92343.2169.560.0407
7101371089.980054/194.09/2.4512.336.82666.8216.120.0407
800480034.683572/73.76/2.517.5237.62480.2167.410.0361
800880066.786784/73.48/3.4810.438.32732.7205.330.0362
8001380010190154/194.34/2.6113.039.13004.9243.520.0362
900490038.993972/73.99/2.667.9839.92790.2188.330.0321
900890075.097584/73.69/3.6911.140.63074.2226.500.0322
10004100043.2104372/74.21/2.808.4142.13100.3209.260.0289
11204112047.3116772/194.45/1.788.9044.53464.9234.530.0258
11208112091.2121184/194.12/2.4712.445.33811.5283.170.0258
125081250102135284/194.35/2.6113.147.94253.9316.040.0232
12504125052.8130372/194.70/1.889.4047.03867.1261.750.0231

The Code Number Is Not The Section

The first column is not a section in square millimetres, even though it looks like one. IEC 61089 D.1.3 defines it as the equivalent conductive area of A1 aluminium — the section of hard-drawn aluminium that would have the same resistance. That is why 125-A1/S1A carries 124.5 mm² of aluminium, not 125, and why the total section is 145.

D.1.4 draws the consequence: conductors with the same code number have the same d.c. resistance, whatever their type, designation or stranding. The table keeps that promise to the fourth decimal. Multiply the resistance by the aluminium area and it lands between 28.7 and 29.0 on every one of the 37 rows:

Row Resistance Ω/km Al area mm² Product
16-17 1.7934 16.0 28.69
125-6 0.2304 124.7 28.73
500-7 0.0578 499.7 28.88
1250-4 0.0231 1249.2 28.86

One number under the whole table, spread over a section range of 78 to 1. Buy on the code number and the resistance is fixed before you choose the steel ratio.

Steel Ratio Runs From 4 To 17 Per Cent

Eight ratios appear, and they are not one tidy series:

Ratio Rows Code numbers
17 % 5 16, 25, 40, 63, 100
16 % 5 125, 160, 200, 250, 315
13 % 7 400, 450, 500, 560, 630, 710, 800
10 % 1 250
8 % 4 800, 900, 1120, 1250
7 % 7 315, 400, 450, 500, 560, 630, 710
6 % 3 125, 160, 200
4 % 5 800, 900, 1000, 1120, 1250

Every code from 16 to 100 mm² is 17 per cent, without an exception. That is not a strength choice on a small conductor, it is the only way a 16 mm² line carries a span: the aluminium alone would not hold. Above 100 the ratio drops to 6 to 16, and at 800 and up it falls again to 4 to 13.

Only one code, 800, appears at three ratios — 4, 8 and 13 per cent — which makes it the one place in the table where you can compare the whole trade at a fixed size:

800 mm² 4 % 8 % 13 %
Steel area mm² 34.6 66.7 101
Total area mm² 835 867 901
Mass kg/km 2480.2 2732.7 3004.9
Rated strength kN 167.41 205.33 243.52
Resistance Ω/km 0.0361 0.0362 0.0362

From 4 to 13 per cent the strength rises 45 per cent and the weight 21, and the resistance moves by a fortieth of a decimal place. Paying for steel at a fixed code buys strength and costs weight, nothing else.

Rated Strength Follows The Steel

Strength per square millimetre of total section runs from 200 to 324 N/mm² across the table — a 60 per cent spread, not the flat material figure you get on an all-aluminium conductor. It is a mixture of two materials, and the mixture moves with the ratio:

  • 16-17: 6.06 kN on 18.7 mm² = 324 N/mm²
  • 125-6: 29.17 on 132 = 221
  • 125-16: 45.69 on 145 = 315
  • 1250-4: 261.75 on 1303 = 201
  • 1250-8: 316.04 on 1352 = 234

At the same code the step from 6 to 16 per cent is worth 57 per cent more strength (125: 29.17 to 45.69), and the weight rises 27 per cent with it. That is the whole trade in one comparison.

One, Seven Or Nineteen Steel Wires

The core is a stranded conductor in its own right, and its wire count climbs with the size:

Steel wires Core diameter Codes
1 1 × d 16 to 200
7 3 × d 125 to 1250
19 5 × d 560 to 1250

The multiples are exact, not rounded — 7 wires give a core of 3d, 19 wires 5d, and every row in the table follows it to the printed decimal (3 × 2.99 = 8.97 against 8.96 printed on 710-7; 5 × 2.18 = 10.9 against 10.9 on 560-13).

The aluminium side is not a simple 6, 12, 18 ladder. IEC 61089 allows a last layer to be partly filled, so the counts run 6, 18, 22, 26, 45, 54, 72, 84 — none of which is a whole multiple of six except the first. The conductor diameter is still core plus two diameters per layer, and every row closes on an integer layer count.

What Is Missing

  • No ampacity. Neither this table nor the standard gives one; it depends on wind, ambient and allowable temperature.
  • No modulus, no expansion coefficient, no sag. A stringing calculation cannot be run from these columns.
  • No A1/S1B, A1/S2A or A1/S2B rows. The standard carries them as Tables D.5 to D.7; they are different steel grades at the same construction, and mixing them into one list would repeat the grade-mixing problem the AAAC page warns about.
  • No GB code column. JL/LB1A is numbered by area over area, not by this code number, so a GB tender cannot be matched row for row here.

The other conductor tables: ACSR / LGJ, AAC / LJ, AAAC / JLHA, AACSR/AW, TACSR, GSW, expanded diameter, ACAR. Back to the designation reference.

Note: Thirty-seven rows from IEC 61089 Table D.4, A1/S1A. The code number is an equivalent aluminium area, not a section: 125 carries 124.5 mm² of aluminium, and resistance times aluminium area stays at 28.7 to 29.0 across all 37 rows, which is D.1.4 holding. Every code from 16 to 100 mm² is 17 per cent steel; 800 is the only code offered at three ratios. Strength per square millimetre runs 200 to 324 N/mm², so this is a mixed-material figure and not a derated single-metal one.