NXL-J Wedge Insulated Strain Clamp (No Stripping)

The NXL-J is the version of the NXL that needs no stripping at all. The insulated conductor goes straight into the wedge as it comes off the drum, which removes the slowest and most error-prone step from a pole-top dead-end, and removes the exposed bare metal that a cover has to close over afterwards. Three bodies cover 35 to 240 mm² with rated failure loads from 14.5 kN to 36.4 kN.
Technical Parameters
| Model | Applicable Conductor (Overhead Insulated Aluminum Conductor) (mm2) | Stripping Length (mm) | Grip Force (kN) | Nominal Failure Load (kN) | Optional Matching Insulation Cover |
|---|---|---|---|---|---|
| NXL-2J | 35 | No stripping required | 3.4 | 14.5 | Optional NXL-2J |
| 50 | 4.6 | ||||
| 70 | 6.7 | ||||
| NXL-3J | 95 | No stripping required | 8.9 | 22.0 | Optional NXL-3J |
| 120 | 11.3 | ||||
| 150 | 13.7 | ||||
| NXL-4J | 185 | No stripping required | 17.3 | 36.4 | Optional NXL-4J |
| 240 | 22.5 |
Note: Cast in high-strength aluminum alloy with no magnetic hysteresis loss. Wedge structure keeps installation simple, and the large arc contact area spreads the grip so the conductor does not slip. Insulation cover is optional rather than supplied as standard.
The Model Numbers Do Not Line Up With the Stripped Version
This is the one thing to get right before ordering. Put NXL-J beside NXL and the numbers collide:
- NXL-2J covers 35, 50 and 70 mm² — which on the stripped version is NXL-1 plus the bottom of NXL-2
- NXL-3J covers 95, 120 and 150 mm² — the top of NXL-2 plus all of NXL-3
- NXL-4J covers 185 and 240 mm² — the same range as NXL-4
So a job specified as “NXL-2” is not an NXL-2J. Each J body reaches one conductor step lower than the standard body carrying the same number, because the clamp has to take the insulation inside the wedge instead of alongside it. Read the conductor column, not the model number.
The same shift shows in the coverage: three J bodies do the work of four standard bodies. Fewer clamps to stock, each doing more range — but only if the crew reads the conductor table rather than the part number.
Load Carried Per Body
Rated failure load steps once per body and never within one: 14.5 kN on NXL-2J, 22.0 kN on NXL-3J, 36.4 kN on NXL-4J. Grip strength runs 3.4 to 22.5 kN across the eight conductor sizes. Set against the rated load, that is a ratio of about 1:4.3 on 35 mm² and 1:1.6 on 240 mm² — the clamp is rated well above what it actually grips, because the rating is set by the body while the grip follows the conductor.
That is worth knowing when a line is designed near the limit. NXL-4J at 36.4 kN is the top of this range — there is no NXL-J for 300 or 400 mm². Above 240 mm² the stripped NXL runs to 400 mm² and 61 kN, and for steel-cored JKLGYJ the NXLJ goes to 70 kN.
Where the Cover Fits
On this clamp the insulation cover is optional, not standard. The stripped NXL ships with a matched cover because bare conductor is exposed at the wedge; the NXL-J does not expose conductor in the first place, so the cover becomes a belt-and-braces measure for wet or polluted routes rather than a dielectric requirement.
Order it by the clamp model — NXL-2J cover for an NXL-2J body — and decide at enquiry whether the route needs it. On a clean rural 10 kV line most crews do not fit one; on a coastal or industrial route with pollution deposits, fit it.
Material and Finish
- Body: high-strength cast aluminum alloy, no magnetic hysteresis loss
- Wedge: aluminum alloy, large arc contact face
- Insulation cover: optional matched polymer cover, ordered by clamp model
- Hardware: hot-dip galvanized steel
- Galvanizing: ISO 1461 / ASTM A153 / IEC 61284, minimum coating 65 μm
- Inspection: dimensional check, coating thickness to ISO 2178, grip test on samples; mill test certificates on request