PF Power Fittings Technical Reference

NY Hydraulic Strain Clamp

Models: NY-50/8 – NY-800/100 (42 sizes) · Conductor: LGJ 50–800 mm² · Grip: 16.1–229 kN · Weight: 1.25–10.75 kg

NY hydraulic compression strain clamp NY hydraulic compression strain clamp, body and jumper tail

NY is the hydraulic compression dead-end for steel-cored aluminium conductor. It does two jobs in one casting: it anchors the conductor, and it carries the jumper. One fitting per string, one press, one set of dies — which is why it is the default dead-end on Chinese overhead practice rather than a plain tube plus a separate jumper support.

The conductor goes into the aluminium barrel at D. The steel core goes into the anchor sleeve at D1. Both are crimped, and the two crimps are what hold the line up; nothing is bolted to the conductor.

The jumper tail is the whole point

Look at the drawing and find L3. It runs from 190 mm on NY-50/8 to 335 mm at 800 mm², and it hangs square to the conductor axis. That is where the jumper is made off, on two or three U-bolts, with the jumper plate either straight (A) or at 30° (B).

If you are pricing NY against a plain compression dead-end, this is the difference. The plain type needs a separate jumper support clamp, a second fitting on the string, and a second set of hardware. NY carries the jumper on the dead-end itself, and the L3 dimension is the length you need to check against the string drawing — not the clamp length.

Two dies, and they are not the same size

A compression dead-end is only as good as its die selection, and NY needs two:

  • D — aluminium barrel outside diameter, 26 to 65 mm. Set by the aluminium area.
  • D1 — steel anchor outside diameter, 12 to 26 mm. Set by the steel area, i.e. the number after the slash.

That is why the two columns do not move together. On the same 50 mm² conductor:

Model D D1 Why
NY-50/8 26 12 thin steel core, small anchor
NY-50/30 30 14 same conductor OD, 30 mm² of steel

And on 400 mm²:

Model D D1 Why
NY-400/20 45 14 20 mm² steel
NY-400/95 48 26 95 mm² steel, biggest anchor on the sheet

Two clamps for a 9.6 mm conductor with barrels 4 mm apart is exactly the mistake that ruins a press job. Order by conductor designation — LGJ-50/30, not 50 mm² — and the dies come out right.

NY hydraulic strain clamp outline drawing

Reading the drawing

  • L — overall length, 355 to 775 mm. This is a string dimension.
  • L1 — from the barrel mouth to the bend, 250 to 630 mm. It is the length you handle on the ground.
  • L2 — palm length at the insulator end, 55 to 100 mm.
  • L3 — jumper tail, 190 to 335 mm.
  • D — aluminium barrel OD, this selects the conductor die.
  • D1 — steel anchor OD, this selects the core die.
  • D2 — neck behind the palm, 16 to 26 mm.
  • R — eye radius at the palm, 10 to 17 mm.

One arithmetic check worth doing before you trust a drawing: L is not L1 + L2. There is another 40 to 65 mm across the bend, and it is not constant. Two rows on the catalogue sheet do not fit the pattern at all — NY-150/8 and NY-300/70 — so if either of those is on your order, work from the drawing rather than the table.

Technical parameters

50 to 400 mm²

ModelApplicable Conductor (mm²)Main Dimensions (mm)Grip Strength (kN)Reference Weight (kg)
LL1L2L3DD1D2R
NY-50/8LGJ-50/8355250551902612161016.1
NY-50/30LGJ-50/30405300551903014161040.51.59
NY-70/10LGJ-70/10385280552002612161022.31.28
NY-70/40LGJ-70/40455350552003218161055.41.90
NY-95/15LGJ-95/15385280552052614161033.31.25
NY-95/20LGJ-95/20385280552052614161035.41.29
NY-95/55LGJ-95/55495380652053420181174.22.26
NY-120/7LGJ-120/7385280552053012161026.2
NY-120/20LGJ-120/20405300552053014161039.01.55
NY-120/25LGJ-120/25425320552053014161045.51.50
NY-120/70LGJ-120/70535420652153622181193.52.66
NY-150/8LGJ-150/8415295552103012161031.31.54
NY-150/20LGJ-150/20435320652103014161044.31.47
NY-150/25LGJ-150/25445330652103014161051.41.59
NY-150/35LGJ-150/35465350652103016161061.81.60
NY-185/25LGJ-185/25465350652303214161056.51.99
NY-185/30LGJ-185/30465350652303216161061.12.03
NY-185/45LGJ-185/45485370652303218181176.22.22
NY-240/30LGJ-240/30505390652303616181171.92.59
NY-240/40LGJ-240/40505390652503616181179.22.59
NY-240/55LGJ-240/55540420652503620201297.02.87
NY-300/15LGJ-300/15495380652504014161064.72.92
NY-300/20LGJ-300/20510390702654014181171.92.92
NY-300/25LGJ-300/25520400702654014181179.32.97
NY-300/40LGJ-300/40540420702654016181187.63.07
NY-300/50LGJ-300/50557430782654018201298.33.23
NY-300/70LGJ-300/705634607826542222213121.63.82
NY-400/20LGJ-400/20560440702704514181184.43.69
NY-400/25LGJ-400/25560440702704514181191.23.62
NY-400/35LGJ-400/35573440782704516201298.73.89
NY-400/50LGJ-400/505934607827045202213117.34.14
NY-400/65LGJ-400/656164807827048222213128.54.22
NY-400/95LGJ-400/956635208027048262415162.85.23

500 to 800 mm²

ModelApplicable Conductor (mm²)Main Dimensions (mm)Grip Strength (kN)Reference Weight (kg)
LL1L2L3DD1D2R
NY-500/35LGJ-500/355984807826052162213113.64.85
NY-500/45LGJ-500/455984807826052182213121.74.90
NY-500/65LGJ-500/656285107826052222213146.34.97
NY-630/45LGJ-630/456084907829060182215141.37.05
NY-630/55LGJ-630/556355108029060202415156.27.34
NY-630/80LGJ-630/806755508029060242415183.39.85
NY-800/55LGJ-800/5572558010033565202617182.010.16
NY-800/70LGJ-800/7077563010033565222617196.7
NY-800/100LGJ-800/10077563010033565262617229.010.75

All dimensions in millimetres, weight per piece. Three rows carry no weight on the factory sheet — NY-50/8, NY-120/7 and NY-800/70 — and we quote those from the drawing rather than guess.

What the grip column actually says

The grip figures are not the fitting’s ultimate strength. They are 95% of the conductor’s calculated breaking load — the acceptance level a compression dead-end has to meet, because the clamp must not be the weak link in the span. Check it yourself: LGJ-240/30 is rated 75.6 kN, the table says 71.9; LGJ-400/35 is rated 103.9 kN, the table says 98.7; LGJ-630/45 is rated 148.7 kN, the table says 141.3.

The practical consequence is that the grip column tells you which conductor the clamp was designed for, not how strong the clamp is. A 229 kN figure at 800 mm² does not mean the body takes 229 kN in every direction; it means the body holds that conductor at its rated load.

NY, JY or JYD

All three are hydraulic compression dead-ends for ACSR, and the conductor range is nearly the same. They are not interchangeable on a string:

Jumper tail Length Weight Use it when
NY yes, L3 190–335 mm 355–775 mm 1.25–10.75 kg the jumper has to land on the dead-end
JY no 300–1050 mm 0.41–6.81 kg separate jumper support, or a yoke/insulator set already fixed
JYD no 280–760 mm 0.43–3.59 kg tight tower window, short string, minimum crimp

The JY and JYD sheets describe the same conductor with the same grip, so the choice between them is about length and die work, not strength.

Crimping

  • Two crimps, conductor end first. Barrel at D, then the core anchor at D1. Crimping the core first leaves no slack to work the barrel down.
  • Strip to the barrel length minus 1–2 mm, and mark the core length on the steel before you cut.
  • Two or three indents on the barrel, one or two on the anchor, worked from the palm toward the mouth.
  • Do not crimp across the bend. The wall thins there and an indent starts a crack that shows up two winters later.
  • The jumper tail is not a crimp. It is a bolted connection — torque it to the U-bolt schedule, and check it again after the jumper is tensioned.
  • Aluminium conductor only. On a copper run, this is the wrong fitting.

The rest of the family

  • NY-G — the same body for steel strand (GJ).
  • NY-BG — aluminium-clad steel strand (JLB).
  • NY-N — heat-resistant alloy conductor, NRLH.
  • NYH — welded body for hollow and large conductors, LGKK and LGJQT.
  • NZ — terminal version of the welded body, no jumper.
  • NLL and NLD — bolted, for when there is no press on site.
  • NXL — wedge type for insulated overhead cable.

Note: Quote by conductor designation and state the jumper angle, A or B. Dimensions are catalogue values; the grip figure belongs to the conductor, not to the clamp. Send the string drawing if L3 has to clear anything.

Sizing data behind this page

The sizes above are nominal. What a conductor of that nominal size actually measures — outer diameter, calculated breaking load, weight per kilometre — is what a clamp groove or a sleeve bore is matched against, and it is in these tables: