NXLJ Wedge Insulated Strain Clamp for JKLGYJ

The NXLJ is the wedge dead-end for JKLGYJ — steel-cored aluminum overhead insulated cable — on 10 kV and below lines. It is a stripped clamp: the insulation comes off over a set length, the bare conductor seats in the wedge, and the insulated cover closes over it. Three bodies cover 35/6 to 240/30, and the ratings are a class above the aluminum-cored clamps because this conductor is designed to be pulled harder.
Technical Parameters
| Universal Design Model | Applicable Conductor (Overhead Steel-reinforced Aluminum Conductor) (mm2) | Stripping Length (mm) | Grip Force (kN) | Nominal Failure Load (kN) | Matching Insulation Cover |
|---|---|---|---|---|---|
| NXLJ-1 | 35/6 | 245 | 8.3 | 38.0 | NXLJ-1 |
| 50/8 | 11.0 | ||||
| 70/10 | 15.3 | ||||
| NXLJ-2 | 95/15 | 300 | 23.0 | 50.0 | NXLJ-2 |
| 120/7 | 18.0 | ||||
| 150/8 | 21.4 | ||||
| NXLJ-3 | 185/10 | 320 | 26.6 | 70.0 | NXLJ-3 |
| 240/30 | 49.2 |
Note: Cast in high-strength aluminum alloy with no magnetic hysteresis loss. Wedge structure keeps installation simple, and the large arc contact area spreads the grip so the conductor does not slip. Dimensions may vary slightly with manufacturing tolerance.
Rated for a Conductor That Pulls
Put these numbers beside the aluminum-cored NXL and the point of the JKLGYJ clamp is obvious: 38.0, 50.0 and 70.0 kN rated, against 7.5 to 36.4 kN on the same conductor sizes in aluminum. The steel core is there to carry tension, and the clamp has to be built to use it.
Only three bodies carry the whole 35/6 to 240/30 range, and the stripping lengths step the same way they do on the aluminum version — 245 mm on NXLJ-1, 300 mm on NXLJ-2, 320 mm on NXLJ-3. On a pole, that 320 mm on NXLJ-3 is the longest strip in the family, so give the crew a tape wrap before they cut.
The Grip Column Does Not Run in Order
Read the grip strengths on NXLJ-2 and they do not behave: 95/15 at 23.0 kN, 120/7 at 18.0 kN, 150/8 at 21.4 kN. The middle conductor is the bigger one and the lower number, which cannot be right as printed.
The clamp is quoted and guaranteed against a rated failure load of 50.0 kN for the body, and the tested grip values go out with the quotation from the type-test report. Where the design depends on the grip of 120/7 specifically, take that figure from the report rather than from the printed 18.0 kN.
The other two bodies read cleanly: 8.3, 11.0 and 15.3 kN on NXLJ-1, and 26.6 against 49.2 kN on NXLJ-3 where the 240/30 conductor nearly doubles the grip of the 185/10.
One Clamp, One Cover
The insulation cover is matched one-to-one with the body here — NXLJ-1 cover on NXLJ-1, and so on — and unlike the no-strip NXL-J it is not optional. The conductor is bare at the wedge on this clamp, so the cover is what restores the dielectric over the joint.
Fit it before the clamp goes up the pole, not after. On a 10 kV line the cover is doing the same job the cable’s own insulation does along the span, and a cover left in the bag is the most common way a correctly specified clamp ends up as a fault.
Material and Finish
- Body: high-strength cast aluminum alloy, no magnetic hysteresis loss
- Wedge: aluminum alloy, large arc contact face
- Insulation cover: matched polymer cover, supplied with the body
- Hardware: hot-dip galvanized steel
- Galvanizing: ISO 1461 / ASTM A153 / IEC 61284, minimum coating 65 μm
- Inspection: dimensional check, coating thickness to ISO 2178, grip test on samples; mill test certificates on request