PF Power Fittings Technical Reference

JBB Parallel Groove Clamp for Steel Strand

Strand: GJ-25 to GJ-240 · Diameter: 6.6 to 20.0 mm · Bolts: 2 or 3

JBB parallel groove clamp for steel strand JBB parallel groove clamp, dimensioned drawing

JBB is the parallel groove clamp for galvanised steel strand — the stay wire and guy-strand end of the trade, not the phase conductor. Same construction as the aluminium clamp: two grooves, a cover plate, two or three bolts, nothing to crimp.

Four sizes take the GB strand range from GJ-25 to GJ-240.

Technical parameters

Model (GB 2008)Applicable steel strandApplicable conductor diameter (mm)Main dimensions (mm)Bolts
LBRM
JBB-1GJ-25~356.6~7.890444.5122
JBB-2GJ-50~707.8~11.090506.0162
JBB-3GJ-100~12013.0~14.0124567.0162
JBB-4GJ-150~24014.5~20.01387010.0163

All dimensions in millimetres. Unlike the aluminium JBG sheet, this one does give the bolt thread: M12 on JBB-1, M16 on the other three. No weight is published.

The ranges do not meet

Read the diameter column as a set, not as a progression, and two gaps appear:

Covered Not covered
6.6 – 7.8 mm
7.8 – 11.0 mm
11.0 – 13.0 mm
13.0 – 14.0 mm
14.0 – 14.5 mm
14.5 – 20.0 mm

The second gap is half a millimetre and will not matter. The first one will. GJ-95 steel strand is nominally about 12 mm outside diameter, which lands squarely in the 11.0 to 13.0 mm hole between JBB-2 and JBB-3. So there is no JBB listed for GJ-95 — check the actual strand diameter against the table rather than assuming a size exists because the neighbours do.

R is the groove radius

R runs 4.5 to 10.0 mm and is the radius of the conductor groove, not a diameter. On the two largest sizes it is exactly half the top of the diameter range — 14.0 mm strand, 7.0 mm groove; 20.0 mm strand, 10.0 mm groove. On JBB-1 and JBB-2 it is slightly generous, 0.5 and 0.6 mm over half the range top.

That difference matters less than it does on an aluminium clamp. Steel strand does not conform. An aluminium conductor yields under the cover plate and fills the groove; a galvanised steel strand does not, so the groove has to be right to begin with and the bolts have to do the rest. This is why the same construction is rated quite differently for steel.

JBB-4 gets a third bolt

L, B, R, M and the bolt count all step up together on JBB-4: 138 mm long, 70 mm wide, 10 mm groove, three bolts instead of two. It is the size that takes GJ-150 through GJ-240, and the extra bolt is there because two would not hold the cover down flat over that much width.

If you are ordering JBB-4, count the bolt holes on the drawing before you specify hardware — a two-bolt assumption will leave you short.

What the sheet does not say

Two things are missing from this sheet that are on the JBG sheet, and both are worth asking for:

  • No materials note. The JBG sheet states that the body and cover plate are aluminium alloy with hot-dip galvanised steel hardware. This one says nothing. Do not assume it carries over — for steel strand the body alloy and the finish on the hardware are exactly what decides whether the joint survives.
  • No weight. So do not quote freight off this page.

Fitting it

  • The groove is not going to close the gap for you. Steel strand keeps its shape, so make sure the strand is in the stated range and not at the very bottom of it.
  • Two or three bolts, in sequence. Pull them down evenly; a cover plate tightened from one end traps the strand on that side and leaves the other groove open.
  • Bonding, not tension. JBB carries current across a joint on a stay or a guard wire. It is not a tension clamp and it is not a strand joint.
  • Check the galvanising on the strand, not just the clamp. A clamp on rusted strand is a joint with a resistor in it.

The rest of the family

  • JBG — the aluminium version for 4.5 to 22 mm conductor.
  • JB — aluminium strand and ACSR.
  • JBT — the general PG clamp with two- and three-bolt bodies.
  • JBT grounding rod — the rod this hardware usually bonds to.

Note: Quote the model and the strand — JBB-4, GJ-210. For GJ-95 there is no JBB listed, so ask before you commit to a size.

Sizing data behind this page

The sizes above are nominal. What a conductor of that nominal size actually measures — outer diameter, calculated breaking load, weight per kilometre — is what a clamp groove or a sleeve bore is matched against, and it is in these tables: