Models: 37 sizes (28 conductor designations) · Reference Weight: 0.4–5.5 kg standard, 3.5–7.0 kg heat-resistant · Body: aluminium, pressed

One Die per Aluminium Section

This is the fact that saves the most money on a TY order. L1, L2 and D depend on the aluminium section only. The steel core changes nothing.

Conductor L1 L2 D Weight
LGJ-185/10 125 90 32 1.4
LGJ-185/25 125 90 32 1.4
LGJ-185/30 125 90 32 1.4
LGJ-400/20 155 120 45 1.9
LGJ-400/35 155 120 45 1.9
LGJ-400/50 155 120 45 1.9
LGJ-400/65 155 120 45 1.9

A 400 mm² line runs five different steel cores in normal Chinese practice, and all five take the same clamp body, the same bore and the same die. Buy the die for the aluminium section and it will press every core variant you have on site.

The one place the steel core does bite is the anchor: which is why TY-400/20-35 and TY-400/50-65 are printed as two model numbers instead of one. Both are 155/120/45/1.9, so the difference is in the steel anchor sleeve, and it matters when you press.

Six Model Numbers Cover Twelve Conductors

Six rows carry a range in the model name rather than a single core size:

Model Covers
TY-95/15/20 LGJ-95/15, LGJ-95/20
TY-185/25-30 LGJ-185/25, LGJ-185/30
TY-240/30-40 LGJ-240/30, LGJ-240/40
TY-300/25-40 LGJ-300/25, LGJ-300/40
TY-400/20-35 LGJ-400/20, /30, /35
TY-400/50-65 LGJ-400/50, /65
TY-500/35-45 LGJ-500/35, /45

Note that TY-185/25-30 and TY-185/30 also both exist as printed rows — the range model and the single model overlap on the 30 core. Both are valid; the single-model row is the one to quote when the conductor is known, the range model when it is not.

The Heat-Resistant Rows Are Twice the Size

Four rows at the bottom of the table are not ACSR and do not share the geometry:

Model Conductor L1 L2 D Weight
TY-300N NRLH60GJ-300 205 295 50 3.5
TY-400N NAHLGJ-400 215 180 55 3.9
TY-500/35N NAHLGJQ-500/35 290 345 65 6.2
TY-630/45N NAHLGJQ-630/45 300 365 70 7.0

Compare TY-300 at 145/110/40 against TY-300N at 205/295/50 — the heat-resistant version is more than twice the length and 45 % heavier for the same nominal section. Heat-resistant aluminium alloy does not take the same compression as ACSR: the wire work-hardens and the joint has to be long, so the fitting is long.

Note also that on three of the four N rows L2 is larger than L1, which is not true anywhere in the standard range. If you are laying these out, L2 is the dimension that grows, and it grows in the branch direction.

Dimension Ladder

For the standard range the ladder is clean and worth carrying in your head:

Section L1 L2 D
35–50 80 60 20
70 100 70 22
95 100 80 26
120 115 80 26
150 125 90 30
185 125 90 32
210 135 100 34
240 135 100 36
300 145 110 40
400 155 120 45
500 165 130 52
630 185 150 60
800 210 170 65

Two sections share a length (95 and 120 both 100/80, 150 and 185 both 125/90) and only the bore steps up. The TL U-bolt T clamp works the same way: fifteen models on three body bores.

Technical Parameters

TY hydraulic T clamp, pressed body

ModelApplicable Conductor (mm2)Main Dimensions (mm)Reference Weight (kg)
L1L2D
TY-35/6LGJ-35/68060200.4
TY-50/8LGJ-50/88060200.5
TY-70/10LGJ-70/1010070220.6
TY-95/15/20LGJ-95/15/2010080260.8
TY-120/7LGJ-120/711580261.2
TY-120/20LGJ-120/2011580261.2
TY-150/8LGJ-150/812590301.3
TY-150/20LGJ-150/2012590301.3
TY-185/10LGJ-185/1012590321.4
TY-185/25-30LGJ-185/2512590321.4
TY-185/25-30LGJ-185/3012590321.4
TY-210/10LGJ-210/10135100341.5
TY-210/25LGJ-210/25135100341.5
TY-240/30-40LGJ-240/30135100361.6
TY-240/30-40LGJ-240/40135100361.6
TY-300/15LGJ-300/15145110401.7
TY-300/20LGJ-300/20145110401.7
TY-300/25-40LGJ-300/25145110401.7
TY-300/25-40LGJ-300/40145110401.7
TY-400/20-35LGJ-400/20155120451.9
TY-400/20-35LGJ-400/30155120451.9
TY-400/20-35LGJ-400/35155120451.9
TY-400/50-65LGJ-400/50155120451.9
TY-400/50-65LGJ-400/65155120451.9
TY-500/35-45LGJ-500/35165130522.3
TY-500/35-45LGJ-500/45165130522.3
TY-500/65LGJ-500/65165130522.3
TY-630/45LGJ-630/45185150604.2
TY-630/55LGJ-630/55185150604.2
TY-630/80LGJ-630/80185150604.2
TY-800/55LGJ-800/55210170655.5
TY-800/70LGJ-800/70210170655.5
TY-800/100LGJ-800/100210170655.5
TY-300NNRLH60GJ-300205295503.5
TY-400NNAHLGJ-400215180553.9
TY-500/35NNAHLGJQ-500/35290345656.2
TY-630/45NNAHLGJQ-630/45300365707.0

TY hydraulic T clamp, branch

Bolted instead of pressed: TL U-bolt T clamp for 7.5–26 mm, TL clamp-plate T clamp for 120–630 mm². Two conductors per phase: TYS compression double conductor clamp. Larger main lines with a pressed branch: TLY compression T clamp.

Note: These are pressed fittings and the die is part of the order. Give the full conductor designation — TY-400/20-35 and TY-400/50-65 share every dimension but not the steel anchor.

Sizing data behind this page

The sizes above are nominal. What a conductor of that nominal size actually measures — outer diameter, calculated breaking load, weight per kilometre — is what a clamp groove or a sleeve bore is matched against, and it is in these tables: