PF Power Fittings Technical Reference

Copper-Aluminum Equipment Clamps and Connection Tubes

Catalogue group: five separate accessory ranges · Dimensions: none published on this sheet

Copper-aluminium connection tubes, braided tape connectors and terminal clamps

The factory files these under one heading, but they are five unrelated hardware ranges that happen to be photographed together: connection tubes, braided tape connectors, compression lugs, small bolted copper-aluminium clamps, and earthing and lightning-protection accessories.

This sheet is a picture index. It carries photographs and captions only — no model numbers, no dimensions, no weights. Each range that has real data has its own page on this site, and this page exists to get you to the right one.

The five groups

Group What is in the photograph Where the data is
Connection tubes aluminium tubes, straight, tee and coupling GTL · GT-G · GL-G
Braided tape connectors flexible copper braid and thin foil straps quoted per item
Compression lugs one- and two-hole palms, eye terminals, threaded studs DTL
Bolted clamps small bolted copper-to-aluminium joints JTL · C type
Earthing and lightning earth rods, earth clamps, H clamps, lightning rods JBT · JDL

1. Connection tubes

Short coupling sleeves, straight tubes in several diameters, and one tee with a branch — the left half of the photograph at the top of this page. One tube carries a small screwed plug, which is the oil-blocking or inspection variant rather than a plain tube.

Plain aluminium tubes are the everyday item; the copper-aluminium version is brazed at one end so that a copper conductor can be jointed to an aluminium one without putting the two metals in direct contact. That bimetallic tube is the GTL, and it is the one that matters when the two sides of a joint are different metals.

2. Braided tape connectors

The right-hand half of the same photograph: flexible copper braid and thin copper foil straps, terminated with bolted plates or crimped flat palms. One of them is a solid curved copper strap rather than a braid.

These are the parts that absorb movement and misalignment — the strap bends so the bolted joints either side do not have to. They are made to the length and the hole spacing of the joint, which is why there is no catalogue table: they are quoted against a dimension sketch, not chosen from a list.

3. Compression lugs and terminals

Compression lugs, eye terminals and a bolted clamp

Four terminations: a two-hole flat palm on a tube, a large eye on a threaded stud, an eye on a tube, and a copper eye lug. These belong to the DT and DTL ranges, where the palms, hole centres and barrel diameters are tabulated — start at the DTL copper-aluminium transition terminal if the terminal is bimetallic, or the DT copper terminal if it is all copper or all aluminium.

4. Small bolted copper-aluminium clamps

Bolted copper-aluminium clamps with copper tongues

The two items at the left of this photograph are bolted clamps with a copper tongue — a slotted body that takes a conductor on one side and a flat copper tongue on the other, closed by a single bolt. They are the small-batch answer for a pad-to-conductor joint where there is neither a press nor room for a compression body.

For the tabulated versions see JTL and the C-type copper connection clamp.

5. Earthing and lightning protection

Earth rods, earth clamps, H clamps and lightning rods

Everything on this sheet sits at the earthing end of the trade:

  • Earth rods — long rods with a driving head at the top and a pointed tip, joined by threaded couplings. The JBT grounding rod page carries the lengths and diameters.
  • Earth clamps — the copper U-clamps and the aluminium H-shaped blocks in the middle, for bonding a conductor to a rod or a structure. See JDL and the piercing grounding clamp.
  • Lightning rods — a single-spike air terminal on a base plate, and the multi-spike ball type with several points radiating from a sphere. The ball version is the one used where the protected area is wide rather than tall.

6. Transformer anti-theft lock

Transformer anti-theft lock, two-piece bolted body

A two-piece bolted body that closes over a nut or a stud so it cannot be undone with a spanner — the factory lists it under transformer anti-theft fittings. There is nothing to dimension: it is ordered against the fastener it has to cover.

What to send for a quote

None of these can be priced from a table, because the sheet has no tables. What is needed instead:

  • Connection tubes — conductor outside diameter on each side, and the tube length.
  • Braided straps — overall length, hole diameter and hole spacing at each end, and the current rating.
  • Lugs — conductor size, stud diameter, and the hole centres if the palm is two-hole.
  • Earth rods — rod diameter, length, and whether a coupling and driving head are needed.
  • Lightning rods — the height and the mounting thread.

The rest of the family

If what you actually need is the main line of equipment clamps rather than these ancillaries, the tabulated ranges are:

  • SLS — bolted twin clamp for ACSR.
  • SY — compression single clamp, plates at 0°, 30° and 90°.
  • SYG — the copper-aluminium compression clamp.
  • JCS — terminal clamp for busbar down-leads.

Note: These are ancillary items. Say what they have to fit — conductor diameter, stud size, hole spacing — and they can be quoted directly from that, without a catalogue number.

Sizing data behind this page

The sizes above are nominal. What a conductor of that nominal size actually measures — outer diameter, calculated breaking load, weight per kilometre — is what a clamp groove or a sleeve bore is matched against, and it is in these tables: